SG4P X.21 Cable Specifications

The SG4P X.21 cable is an HD62 to 4 x DB15 male connections. To retain FCC Class A qualification all cables must be fully shielded and the shielding must be connected to the metal connectors.
P1 -- HD62 Male with screws --- |--- P2 -- DB15 Male
|--- P3 -- DB15 Male
|--- P4 -- DB15 Male
|--- P5 -- DB15 Male

P1

 

P2

 

P1

 

P3

20
Tx Data0 - A
2
15
Tx Data1 - A
2
19
RTS0 - A
3
14
RTS1 - A
3
18
Rx Data0 - A
4
13
Rx Data1 - A
4
17
DCD0 - A
5
12
DCD1 - A
5
42
Clock0 - A
6
37
Clock1 - A
6
40
Ground
8
35
Ground
8
39
Tx Data0 - B
9
34
Tx Data1 - B
9
38
RTS0 - B
10
33
RTS1 - B
10
62
Rx Data0 - B
11
57
Rx Data1 - B
11
61
DCD0 - B
12
56
DCD1 - B
12
60
Clock0 - B
13
55
Clock1 - B
13

P1

 

P3

 

P1

 

P4

9
Tx Data2 - A
2
4
Tx Data3 - A
2
8
RTS2 - A
3
3
RTS3 - A
3
7
Rx Data2 - A
4
2
Rx Data3 - A
4
6
DCD2 - A
5
1
DCD3 - A
5
31
Clock2 - A
6
26
Clock3 - A
6
29
Ground
8
24
Ground
8
28
Tx Data2 - B
9
23
Tx Data3 - B
9
27
RTS2 - B
10
22
RTS3 - B
10
52
Rx Data2 - B
11
47
Rx Data3 - B
11
51
DCD2 - B
12
46
DCD3 - B
12
50
Clock2 - B
13
45
Clock3 - B
13

Use shielded cable approx. 6 feet in length and for the HD62 use a metalized plastic covers. Ensure the shielding is soldered to the metal of the connectors (HD62 and DB15).Label each cable near the DB15 connectors as follows:
P2 - Link 0

P3 - Link 1

P4 - Link 2

P5 - Link 3
Rx=Receive, Tx=Transmit, CTS=Clear to Send, RTS=Ready to Send,
DTR=Data Terminal Ready, DSR=Data Set Ready, DCD=Data Carrier Detect